OSO Delta Powercyl DCF300 Litre Indirect Unvented Cylinder (11009125)

£1,968.00 incl. vat
£1,640.00 excl. vat

Available on back-order

Description

OSO Delta Powercyl DCF300 Litre Indirect Unvented Cylinder (11009125)

DELTA POWERCYL — DCF can deliver nearly double the flow rates (up to 5bar) of a standard cylinder with its 1” connections. DCF is an ideal choice for small hotels/ guesthouses with multiple showers/baths. a 1- 6 bar adjustable PRV valve and oversized expansion vessel are supplied as standard.

DCF is a perfect partner to the SUPERSTREAM system where mains flow rates are insufficient. DELTA series is the most efficient hot water cylinder available utilizing unique Vacuum Panel Insulation.

DELTA series is a part of the award-winning Delta Coil range, and through the incorporation of Vacuum Insulation Panels it can save enough energy to pay for the entire cylinder over its lifetime.

Delta Powercyl can be controlled either via using a thermistor probe or its own digital thermostat with digital display of water temperature.

Features:

  • 1” connections for high flow rates
  • Reduces heat loss by 400 kWh* / year with NANOPUR and VIP*
  • Helps housebuilders achieve SAP energy requirements
  • 25 year warranty on the stainless steel tank
  • Smooth scale resistant coil
  • Delta has holiday and anti-legionalla functionality.

Advantages:

  • DELTA DESIGN – Elegant and functional
  • NANOPUR – Class-leading insulation
  • VACUUM – Ultimate performance
  • ULTRAWELD – Superior corrosion resistance
  • INCOTEC – High durability in hard water
  • SMOOTH COIL – Does not encourage limescale build-up
  • ECO-HOTWATER – DHW from alternative energy

Technical Specifications:

Product name DCF 300 - 3 kW / 1 × 230 V + HX 0,8 m²
Diameter (mm) 595
Height (mm) 1750
Weight (kg) 340
Weight empty (kg) 61
Capacity 40C (L) 447
Volume (L) 284
Thermostat set point (C) 60
Heat loss-EN 12897 (watt) 49
Heat loss / 24 hrs – EN 12897 (kWh/day) 1.18
AEC (energy consumption) (kW/year) N / A
Energy efficiency (%) N / A
Tapping profile (3XS–XXL) N / A
Energy rating (A+–F) A
Primary Heating Power (kW) 32
Primary coil size (mins) 1.8
Immersion Heating Power (kW) 3
Heat-up time ΔT 55°C Coil (mins) 26
Heat-up time ΔT 55°C upper element (mins) N / A
Heat-up time ΔT 55°C lower element (min) N / A
Recovery time ΔT 55°C coil 70% (mins) 18
Recovery time ΔT 55°C upper element 70 (mins) N / A
Recovery time ΔT 55°C lower element 70% (mins) N / A

Click here to view Data Sheet.